Description

Product Name Hall Effect Current Sensor Split Core Transducer
P/N MLRH-2147
Primary Rated Current 20/50/100/200A/300A/400A
Output Voltage Single Power 2.5±2V
Dual Power Dual Power 0±4V
Insulation withstand voltage 3KV/1min
 Operating Frequency 50-60Hz
  Operating Temperature -40℃ ~ +85℃
Insulation Epoxy resin encapsulated
Outer Case  Flame Retardant PBT
Application Variable frequency electrical appliances, inverter, AC/DC variable-speed driveSwitched Mode Power Supplies (SMPS), Uninterruptible Power Supplies (UPS),

Features

Easy installation

Window structure

Low power consumption, very good linearity

Only one design for wide current ratings range

High immunity to external interference

No insertion losses

Dual Power Hall Current Sensor

Electrical data (Ta=25ºC±5ºC)

Rated input IPN 20/50/100 A
Measuring range IP ±30/±75/±150 A
Output voltage Vo ±4.0*(IP/IPN) V
Load resistance RL >10
Supply voltage VC (±12 ~±15) ±5% V
Accuracy XG @IPN,T=25°C < ±1.0 %
Offset voltage VOE @IP=0,T=25°C < ±25 mV
Temperature variation of VOE VOT @IP=0,-40 ~ +85°C < ±1.0/< ±0.5/< ±0.5 mV/℃
Temperature variation of VO VOS @IP=IPN,-40 ~ +85°C < ±2.5 %
Hysteresis offset voltage VOH @IP=0,after 1*IPN < ±25 mV
Linearity error εr < 1.0 %FS
di/dt > 100 A/μs
Response time tra @90% of IPN < 5.0 μs
Power consumption IC @+15V <23 mA
@-15V <4.5 mA
Bandwidth BW @-3dB,IPN DC-20 KHZ
Insulation voltage Vd @50/60Hz, 1min,AC ,1.5mA 4.0 KV

 

Ring Type Electrical data:(Ta=25°C,Vc=+12.0VDC,RL=2KΩ)

Parameter

MLRH-50A/2V

MLRH-100A/2V

MLRH-200A/2V

MLRH-300A/2V

MLRH-400A/2V

Unit

Rated input

IPN

50

100

200

300

400

A

Measuring range

IP

0~±50

0~±100

0~±200

0~±300

0~±400

A

Output voltage

Vo

2.500±2.0*(IP/IPN)

V

Output voltage

Vo

@IP=0,T=25°C

2.500

V

Load resistance

RL

>2

KΩ

  Supply voltage

VC

+12.0 ±5%

V

   Accuracy

XG

@IPN,T=25°C

< ±1.0

%

  Offset voltage

VOE

@IP=0,T=25°C

< ±25

mV

Temperature variation of VOE

VOT

@IP=0,-40 ~ +85°C

< ±1.0

mV/℃

Hysteresis offset voltage

VOH

@IP=0,after  1*IPN

< ±20

mV

Linearity error

εr

 < 1.0

%FS

di/dt

 > 100

A/µs

Response time

tra

@90% of IPN < 3.0

µs

Power consumption

IC

15

mA

Bandwidth

BW

@-3dB,IPN

DC-20

KHZ

Insulation voltage

Vd

@50/60Hz, 1min,AC

2.5

KV

General data:

参数 Parameter

符号Symbol

数值Value

单位Unit

Operating temperature

TA

-40 ~ +85

°C

Storage temperature

Ts

-55~ +125

°C

Weight

m

70

g

Plastic material

PBT G30/G15,UL94- V0;

Standards

IEC60950-1:2001

EN50178:1998

SJ20790-2000

 

Dimensions (mm):

222

Remarks:

1,When the current will be measured goes through the primary pin of a sensor, the voltage will beMeasured at the output end. (Note: The false wiring may result in the damage the sensor).

2,Custom design in the different rated input current and the output voltage are available.

3,The dynamic performance is the best when the primary hole if fully filled with;

4, The primary conductor should be <100°C;

 

8

Rectangular Type Electrical data:(Ta=25°C,Vc=+12.0VDC,RL=2KΩ)

Parameter

MLRH-200A/2V

MLRH 4-600A/2V

MLRH 4-800A/2V

MLRH 4-1000A/2V

MLRH 4-1200A/2V

MLRH 4-2000A/2V

Unit

  Rated input

IPN

200

600

800

1000

1200

2000

A

Measuring range

IP

0~±200

0~±600

0~±800

0~±1000

0~±1200

0~±2000

A

Output voltage

Vo

2.500±2.0*(IP/IPN)

V

Output voltage

Vo

@IP=0,T=25°C

2.500

V

Load resistance

RL

>2

KΩ

Supply voltage

VC

+12.0±5%

V

Accuracy

XG

@IPN,T=25°C

< ±1.0

%

Offset voltage

VOE

@IP=0,T=25°C

< ±25

mV

Temperature variation of VOE

VOT

@IP=0,-40 ~ +85°C

< ±1.0

mV/℃

Hysteresis offset voltage

VOH

@IP=0,after  1*IPN

< ±20

mV

Linearity error

εr

                    < 1.0

%FS

di/dt

                    > 100

A/µs

Response time

tra

@90% of IPN                     < 7.0

µs

Power consumption

IC

15

mA

Bandwidth

BW

@-3dB,IPN

DC-20

KHZ

Insulation voltage

Vd

@50/60Hz, 1min,AC

6.0

KV

 

General data:

参数 Parameter

符号Symbol

数值Value

单位Unit

Operating temperature

TA

-40 ~ +85

°C

Storage temperature

Ts

-55~ +125

°C

Weight

m

200

g

Plastic material

PBT G30/G15,UL94- V0;

Standards

IEC60950-1:2001

EN50178:1998

SJ20790-2000

 

Dimensions (mm):

111

Remarks:

1, When the current will be measured goes through the primary pin of a sensor, the voltage will be

Measured at the output end.(Note: The false wiring may result in the damage  the sensor).

2, Custom design in the different rated input current and the output voltage are available.

3, The dynamic performance is the best when the primary hole if fully filled with;

4, The primary conductor should be <100°C;

10


Product detail pictures:

Bottom price 150a 4v Hall Effect Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

Bottom price 150a 4v Hall Effect Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

Bottom price 150a 4v Hall Effect Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

Bottom price 150a 4v Hall Effect Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

Bottom price 150a 4v Hall Effect Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

Bottom price 150a 4v Hall Effect Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures


Related Product Guide:

We've been proud with the significant shopper fulfillment and wide acceptance due to our persistent pursuit of top of the range both of those on solution and repair for Bottom price 150a 4v Hall Effect Current Transformer - Hall Effect Current Sensor Split Core Transducer – Malio , The product will supply to all over the world, such as: Bulgaria, Malawi, Algeria, All of our products comply with international quality standards and are greatly appreciated in a variety of markets around the world. If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us. We are looking forward to forming successful business relationships with new clients in the near future.
  • We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Federico Michael Di Marco from Victoria - 2017.08.18 18:38
    The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Georgia from Jakarta - 2017.11.12 12:31
    Write your message here and send it to us