We have our own sales team, design team, technical team, QC team and package team. We have strict quality control procedures for each process. Also, all of our workers are experienced in printing field for Lcd Glass Panel, High Permeability Transformer Core, Current Transformer For Electricity Meter, Only for accomplish the good-quality product or service to satisfy customer's demand, all of our products have been strictly inspected before shipment.
China OEM Three Phase Combined Current Transformer - Hall Effect Current Sensor Split Core Transducer – Malio Detail:

Description

Product Name Hall Effect Current Sensor Split Core Transducer
P/N MLRH-2147
Primary Rated Current 20/50/100/200A/300A/400A
Output Voltage Single Power 2.5±2V
Dual Power Dual Power 0±4V
Insulation withstand voltage 3KV/1min
 Operating Frequency 50-60Hz
  Operating Temperature -40℃ ~ +85℃
Insulation Epoxy resin encapsulated
Outer Case  Flame Retardant PBT
Application Variable frequency electrical appliances, inverter, AC/DC variable-speed driveSwitched Mode Power Supplies (SMPS), Uninterruptible Power Supplies (UPS),

Features

Easy installation

Window structure

Low power consumption, very good linearity

Only one design for wide current ratings range

High immunity to external interference

No insertion losses

Dual Power Hall Current Sensor

Electrical data (Ta=25ºC±5ºC)

Rated input IPN 20/50/100 A
Measuring range IP ±30/±75/±150 A
Output voltage Vo ±4.0*(IP/IPN) V
Load resistance RL >10
Supply voltage VC (±12 ~±15) ±5% V
Accuracy XG @IPN,T=25°C < ±1.0 %
Offset voltage VOE @IP=0,T=25°C < ±25 mV
Temperature variation of VOE VOT @IP=0,-40 ~ +85°C < ±1.0/< ±0.5/< ±0.5 mV/℃
Temperature variation of VO VOS @IP=IPN,-40 ~ +85°C < ±2.5 %
Hysteresis offset voltage VOH @IP=0,after 1*IPN < ±25 mV
Linearity error εr < 1.0 %FS
di/dt > 100 A/μs
Response time tra @90% of IPN < 5.0 μs
Power consumption IC @+15V <23 mA
@-15V <4.5 mA
Bandwidth BW @-3dB,IPN DC-20 KHZ
Insulation voltage Vd @50/60Hz, 1min,AC ,1.5mA 4.0 KV

 

Ring Type Electrical data:(Ta=25°C,Vc=+12.0VDC,RL=2KΩ)

Parameter

MLRH-50A/2V

MLRH-100A/2V

MLRH-200A/2V

MLRH-300A/2V

MLRH-400A/2V

Unit

Rated input

IPN

50

100

200

300

400

A

Measuring range

IP

0~±50

0~±100

0~±200

0~±300

0~±400

A

Output voltage

Vo

2.500±2.0*(IP/IPN)

V

Output voltage

Vo

@IP=0,T=25°C

2.500

V

Load resistance

RL

>2

KΩ

  Supply voltage

VC

+12.0 ±5%

V

   Accuracy

XG

@IPN,T=25°C

< ±1.0

%

  Offset voltage

VOE

@IP=0,T=25°C

< ±25

mV

Temperature variation of VOE

VOT

@IP=0,-40 ~ +85°C

< ±1.0

mV/℃

Hysteresis offset voltage

VOH

@IP=0,after  1*IPN

< ±20

mV

Linearity error

εr

 < 1.0

%FS

di/dt

 > 100

A/µs

Response time

tra

@90% of IPN < 3.0

µs

Power consumption

IC

15

mA

Bandwidth

BW

@-3dB,IPN

DC-20

KHZ

Insulation voltage

Vd

@50/60Hz, 1min,AC

2.5

KV

General data:

参数 Parameter

符号Symbol

数值Value

单位Unit

Operating temperature

TA

-40 ~ +85

°C

Storage temperature

Ts

-55~ +125

°C

Weight

m

70

g

Plastic material

PBT G30/G15,UL94- V0;

Standards

IEC60950-1:2001

EN50178:1998

SJ20790-2000

 

Dimensions (mm):

222

Remarks:

1,When the current will be measured goes through the primary pin of a sensor, the voltage will beMeasured at the output end. (Note: The false wiring may result in the damage the sensor).

2,Custom design in the different rated input current and the output voltage are available.

3,The dynamic performance is the best when the primary hole if fully filled with;

4, The primary conductor should be <100°C;

 

8

Rectangular Type Electrical data:(Ta=25°C,Vc=+12.0VDC,RL=2KΩ)

Parameter

MLRH-200A/2V

MLRH 4-600A/2V

MLRH 4-800A/2V

MLRH 4-1000A/2V

MLRH 4-1200A/2V

MLRH 4-2000A/2V

Unit

  Rated input

IPN

200

600

800

1000

1200

2000

A

Measuring range

IP

0~±200

0~±600

0~±800

0~±1000

0~±1200

0~±2000

A

Output voltage

Vo

2.500±2.0*(IP/IPN)

V

Output voltage

Vo

@IP=0,T=25°C

2.500

V

Load resistance

RL

>2

KΩ

Supply voltage

VC

+12.0±5%

V

Accuracy

XG

@IPN,T=25°C

< ±1.0

%

Offset voltage

VOE

@IP=0,T=25°C

< ±25

mV

Temperature variation of VOE

VOT

@IP=0,-40 ~ +85°C

< ±1.0

mV/℃

Hysteresis offset voltage

VOH

@IP=0,after  1*IPN

< ±20

mV

Linearity error

εr

                    < 1.0

%FS

di/dt

                    > 100

A/µs

Response time

tra

@90% of IPN                     < 7.0

µs

Power consumption

IC

15

mA

Bandwidth

BW

@-3dB,IPN

DC-20

KHZ

Insulation voltage

Vd

@50/60Hz, 1min,AC

6.0

KV

 

General data:

参数 Parameter

符号Symbol

数值Value

单位Unit

Operating temperature

TA

-40 ~ +85

°C

Storage temperature

Ts

-55~ +125

°C

Weight

m

200

g

Plastic material

PBT G30/G15,UL94- V0;

Standards

IEC60950-1:2001

EN50178:1998

SJ20790-2000

 

Dimensions (mm):

111

Remarks:

1, When the current will be measured goes through the primary pin of a sensor, the voltage will be

Measured at the output end.(Note: The false wiring may result in the damage  the sensor).

2, Custom design in the different rated input current and the output voltage are available.

3, The dynamic performance is the best when the primary hole if fully filled with;

4, The primary conductor should be <100°C;

10


Product detail pictures:

China OEM Three Phase Combined Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

China OEM Three Phase Combined Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

China OEM Three Phase Combined Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

China OEM Three Phase Combined Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

China OEM Three Phase Combined Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

China OEM Three Phase Combined Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures


Related Product Guide:

We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate inside our success for China OEM Three Phase Combined Current Transformer - Hall Effect Current Sensor Split Core Transducer – Malio , The product will supply to all over the world, such as: Slovenia, Finland, Adelaide, Actually need to any of those objects be of interest to you, make sure you allow us to know. We'll be delighted to present you a quotation on receipt of one's comprehensive specs. We've our individual specialist R&D enginners to meet any of the requriements, We look forward to receiving your enquires soon and hope to have the chance to work together with you inside the future. Welcome to take a look at our organization.
  • This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Ellen from Swiss - 2018.09.29 17:23
    In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
    5 Stars By Arlene from Chicago - 2017.02.14 13:19
    Write your message here and send it to us