Our advancement depends over the superior machines, exceptional talents and continually strengthened technology forces for Clip On Current Transformer, Cage Terminal Assembly, Split Core Cts, We have professional products knowledge and rich experience on manufacturing. We always believe your success is our business!
High Quality Current Transformer For Smart Meter - Hall Effect Current Sensor Split Core Transducer – Malio Detail:

Description

Product Name Hall Effect Current Sensor Split Core Transducer
P/N MLRH-2147
Primary Rated Current 20/50/100/200A/300A/400A
Output Voltage Single Power 2.5±2V
Dual Power Dual Power 0±4V
Insulation withstand voltage 3KV/1min
 Operating Frequency 50-60Hz
  Operating Temperature -40℃ ~ +85℃
Insulation Epoxy resin encapsulated
Outer Case  Flame Retardant PBT
Application Variable frequency electrical appliances, inverter, AC/DC variable-speed driveSwitched Mode Power Supplies (SMPS), Uninterruptible Power Supplies (UPS),

Features

Easy installation

Window structure

Low power consumption, very good linearity

Only one design for wide current ratings range

High immunity to external interference

No insertion losses

Dual Power Hall Current Sensor

Electrical data (Ta=25ºC±5ºC)

Rated input IPN 20/50/100 A
Measuring range IP ±30/±75/±150 A
Output voltage Vo ±4.0*(IP/IPN) V
Load resistance RL >10
Supply voltage VC (±12 ~±15) ±5% V
Accuracy XG @IPN,T=25°C < ±1.0 %
Offset voltage VOE @IP=0,T=25°C < ±25 mV
Temperature variation of VOE VOT @IP=0,-40 ~ +85°C < ±1.0/< ±0.5/< ±0.5 mV/℃
Temperature variation of VO VOS @IP=IPN,-40 ~ +85°C < ±2.5 %
Hysteresis offset voltage VOH @IP=0,after 1*IPN < ±25 mV
Linearity error εr < 1.0 %FS
di/dt > 100 A/μs
Response time tra @90% of IPN < 5.0 μs
Power consumption IC @+15V <23 mA
@-15V <4.5 mA
Bandwidth BW @-3dB,IPN DC-20 KHZ
Insulation voltage Vd @50/60Hz, 1min,AC ,1.5mA 4.0 KV

 

Ring Type Electrical data:(Ta=25°C,Vc=+12.0VDC,RL=2KΩ)

Parameter

MLRH-50A/2V

MLRH-100A/2V

MLRH-200A/2V

MLRH-300A/2V

MLRH-400A/2V

Unit

Rated input

IPN

50

100

200

300

400

A

Measuring range

IP

0~±50

0~±100

0~±200

0~±300

0~±400

A

Output voltage

Vo

2.500±2.0*(IP/IPN)

V

Output voltage

Vo

@IP=0,T=25°C

2.500

V

Load resistance

RL

>2

KΩ

  Supply voltage

VC

+12.0 ±5%

V

   Accuracy

XG

@IPN,T=25°C

< ±1.0

%

  Offset voltage

VOE

@IP=0,T=25°C

< ±25

mV

Temperature variation of VOE

VOT

@IP=0,-40 ~ +85°C

< ±1.0

mV/℃

Hysteresis offset voltage

VOH

@IP=0,after  1*IPN

< ±20

mV

Linearity error

εr

 < 1.0

%FS

di/dt

 > 100

A/µs

Response time

tra

@90% of IPN < 3.0

µs

Power consumption

IC

15

mA

Bandwidth

BW

@-3dB,IPN

DC-20

KHZ

Insulation voltage

Vd

@50/60Hz, 1min,AC

2.5

KV

General data:

参数 Parameter

符号Symbol

数值Value

单位Unit

Operating temperature

TA

-40 ~ +85

°C

Storage temperature

Ts

-55~ +125

°C

Weight

m

70

g

Plastic material

PBT G30/G15,UL94- V0;

Standards

IEC60950-1:2001

EN50178:1998

SJ20790-2000

 

Dimensions (mm):

222

Remarks:

1,When the current will be measured goes through the primary pin of a sensor, the voltage will beMeasured at the output end. (Note: The false wiring may result in the damage the sensor).

2,Custom design in the different rated input current and the output voltage are available.

3,The dynamic performance is the best when the primary hole if fully filled with;

4, The primary conductor should be <100°C;

 

8

Rectangular Type Electrical data:(Ta=25°C,Vc=+12.0VDC,RL=2KΩ)

Parameter

MLRH-200A/2V

MLRH 4-600A/2V

MLRH 4-800A/2V

MLRH 4-1000A/2V

MLRH 4-1200A/2V

MLRH 4-2000A/2V

Unit

  Rated input

IPN

200

600

800

1000

1200

2000

A

Measuring range

IP

0~±200

0~±600

0~±800

0~±1000

0~±1200

0~±2000

A

Output voltage

Vo

2.500±2.0*(IP/IPN)

V

Output voltage

Vo

@IP=0,T=25°C

2.500

V

Load resistance

RL

>2

KΩ

Supply voltage

VC

+12.0±5%

V

Accuracy

XG

@IPN,T=25°C

< ±1.0

%

Offset voltage

VOE

@IP=0,T=25°C

< ±25

mV

Temperature variation of VOE

VOT

@IP=0,-40 ~ +85°C

< ±1.0

mV/℃

Hysteresis offset voltage

VOH

@IP=0,after  1*IPN

< ±20

mV

Linearity error

εr

                    < 1.0

%FS

di/dt

                    > 100

A/µs

Response time

tra

@90% of IPN                     < 7.0

µs

Power consumption

IC

15

mA

Bandwidth

BW

@-3dB,IPN

DC-20

KHZ

Insulation voltage

Vd

@50/60Hz, 1min,AC

6.0

KV

 

General data:

参数 Parameter

符号Symbol

数值Value

单位Unit

Operating temperature

TA

-40 ~ +85

°C

Storage temperature

Ts

-55~ +125

°C

Weight

m

200

g

Plastic material

PBT G30/G15,UL94- V0;

Standards

IEC60950-1:2001

EN50178:1998

SJ20790-2000

 

Dimensions (mm):

111

Remarks:

1, When the current will be measured goes through the primary pin of a sensor, the voltage will be

Measured at the output end.(Note: The false wiring may result in the damage  the sensor).

2, Custom design in the different rated input current and the output voltage are available.

3, The dynamic performance is the best when the primary hole if fully filled with;

4, The primary conductor should be <100°C;

10


Product detail pictures:

High Quality Current Transformer For Smart Meter - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

High Quality Current Transformer For Smart Meter - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

High Quality Current Transformer For Smart Meter - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

High Quality Current Transformer For Smart Meter - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

High Quality Current Transformer For Smart Meter - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

High Quality Current Transformer For Smart Meter - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures


Related Product Guide:

To be able to ideal satisfy client's requirements, all of our operations are strictly performed in line with our motto "High High-quality, Competitive Price tag, Fast Service" for High Quality Current Transformer For Smart Meter - Hall Effect Current Sensor Split Core Transducer – Malio , The product will supply to all over the world, such as: Jordan, Kazakhstan, Singapore, We have more than 200 staff including experienced managers, creative designers, sophisticated engineers and skilled workers. Through hard work of all employees for the past 20 years own company grew stronger and stronger. We always apply the "client first" principle. We also always fulfill all contracts to the point and therefore enjoy excellent reputation and trust among our customers. You are very welcome to personally visit our company.We hope to start a business partnership on the basis of mutual benefit and successful development . For more information please do no hesitate to contact us..
  • This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Dee Lopez from Holland - 2018.09.23 17:37
    In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
    5 Stars By Sara from South Korea - 2017.08.28 16:02
    Write your message here and send it to us