• news

OEM China Three Phase Current Transformer - Hall Effect Current Sensor Split Core Transducer – Malio


Product Detail

Product Tags

Related Video

Feedback (2)

We insist on the principle of development of 'High quality, Efficiency, Sincerity and Down-to-earth working approach' to provide you with excellent service of processing for Electrical Meter Brass Terminal, Lcd Glass Panel, 0.5 Accuracy Hall Effect Current Sensor, We're searching ahead to setting up long-term company associations with you. Your comments and solutions are remarkably appreciated.
OEM China Three Phase Current Transformer - Hall Effect Current Sensor Split Core Transducer – Malio Detail:

Description

Product Name Hall Effect Current Sensor Split Core Transducer
P/N MLRH-2147
Primary Rated Current 20/50/100/200A/300A/400A
Output Voltage Single Power 2.5±2V
Dual Power Dual Power 0±4V
Insulation withstand voltage 3KV/1min
 Operating Frequency 50-60Hz
  Operating Temperature -40℃ ~ +85℃
Insulation Epoxy resin encapsulated
Outer Case  Flame Retardant PBT
Application Variable frequency electrical appliances, inverter, AC/DC variable-speed driveSwitched Mode Power Supplies (SMPS), Uninterruptible Power Supplies (UPS),

Features

Easy installation

Window structure

Low power consumption, very good linearity

Only one design for wide current ratings range

High immunity to external interference

No insertion losses

Dual Power Hall Current Sensor

Electrical data (Ta=25ºC±5ºC)

Rated input IPN 20/50/100 A
Measuring range IP ±30/±75/±150 A
Output voltage Vo ±4.0*(IP/IPN) V
Load resistance RL >10
Supply voltage VC (±12 ~±15) ±5% V
Accuracy XG @IPN,T=25°C < ±1.0 %
Offset voltage VOE @IP=0,T=25°C < ±25 mV
Temperature variation of VOE VOT @IP=0,-40 ~ +85°C < ±1.0/< ±0.5/< ±0.5 mV/℃
Temperature variation of VO VOS @IP=IPN,-40 ~ +85°C < ±2.5 %
Hysteresis offset voltage VOH @IP=0,after 1*IPN < ±25 mV
Linearity error εr < 1.0 %FS
di/dt > 100 A/μs
Response time tra @90% of IPN < 5.0 μs
Power consumption IC @+15V <23 mA
@-15V <4.5 mA
Bandwidth BW @-3dB,IPN DC-20 KHZ
Insulation voltage Vd @50/60Hz, 1min,AC ,1.5mA 4.0 KV

 

Ring Type Electrical data:(Ta=25°C,Vc=+12.0VDC,RL=2KΩ)

Parameter

MLRH-50A/2V

MLRH-100A/2V

MLRH-200A/2V

MLRH-300A/2V

MLRH-400A/2V

Unit

Rated input

IPN

50

100

200

300

400

A

Measuring range

IP

0~±50

0~±100

0~±200

0~±300

0~±400

A

Output voltage

Vo

2.500±2.0*(IP/IPN)

V

Output voltage

Vo

@IP=0,T=25°C

2.500

V

Load resistance

RL

>2

KΩ

  Supply voltage

VC

+12.0 ±5%

V

   Accuracy

XG

@IPN,T=25°C

< ±1.0

%

  Offset voltage

VOE

@IP=0,T=25°C

< ±25

mV

Temperature variation of VOE

VOT

@IP=0,-40 ~ +85°C

< ±1.0

mV/℃

Hysteresis offset voltage

VOH

@IP=0,after  1*IPN

< ±20

mV

Linearity error

εr

 < 1.0

%FS

di/dt

 > 100

A/µs

Response time

tra

@90% of IPN < 3.0

µs

Power consumption

IC

15

mA

Bandwidth

BW

@-3dB,IPN

DC-20

KHZ

Insulation voltage

Vd

@50/60Hz, 1min,AC

2.5

KV

General data:

参数 Parameter

符号Symbol

数值Value

单位Unit

Operating temperature

TA

-40 ~ +85

°C

Storage temperature

Ts

-55~ +125

°C

Weight

m

70

g

Plastic material

PBT G30/G15,UL94- V0;

Standards

IEC60950-1:2001

EN50178:1998

SJ20790-2000

 

Dimensions (mm):

222

Remarks:

1,When the current will be measured goes through the primary pin of a sensor, the voltage will beMeasured at the output end. (Note: The false wiring may result in the damage the sensor).

2,Custom design in the different rated input current and the output voltage are available.

3,The dynamic performance is the best when the primary hole if fully filled with;

4, The primary conductor should be <100°C;

 

8

Rectangular Type Electrical data:(Ta=25°C,Vc=+12.0VDC,RL=2KΩ)

Parameter

MLRH-200A/2V

MLRH 4-600A/2V

MLRH 4-800A/2V

MLRH 4-1000A/2V

MLRH 4-1200A/2V

MLRH 4-2000A/2V

Unit

  Rated input

IPN

200

600

800

1000

1200

2000

A

Measuring range

IP

0~±200

0~±600

0~±800

0~±1000

0~±1200

0~±2000

A

Output voltage

Vo

2.500±2.0*(IP/IPN)

V

Output voltage

Vo

@IP=0,T=25°C

2.500

V

Load resistance

RL

>2

KΩ

Supply voltage

VC

+12.0±5%

V

Accuracy

XG

@IPN,T=25°C

< ±1.0

%

Offset voltage

VOE

@IP=0,T=25°C

< ±25

mV

Temperature variation of VOE

VOT

@IP=0,-40 ~ +85°C

< ±1.0

mV/℃

Hysteresis offset voltage

VOH

@IP=0,after  1*IPN

< ±20

mV

Linearity error

εr

                    < 1.0

%FS

di/dt

                    > 100

A/µs

Response time

tra

@90% of IPN                     < 7.0

µs

Power consumption

IC

15

mA

Bandwidth

BW

@-3dB,IPN

DC-20

KHZ

Insulation voltage

Vd

@50/60Hz, 1min,AC

6.0

KV

 

General data:

参数 Parameter

符号Symbol

数值Value

单位Unit

Operating temperature

TA

-40 ~ +85

°C

Storage temperature

Ts

-55~ +125

°C

Weight

m

200

g

Plastic material

PBT G30/G15,UL94- V0;

Standards

IEC60950-1:2001

EN50178:1998

SJ20790-2000

 

Dimensions (mm):

111

Remarks:

1, When the current will be measured goes through the primary pin of a sensor, the voltage will be

Measured at the output end.(Note: The false wiring may result in the damage  the sensor).

2, Custom design in the different rated input current and the output voltage are available.

3, The dynamic performance is the best when the primary hole if fully filled with;

4, The primary conductor should be <100°C;

10


Product detail pictures:

OEM China Three Phase Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

OEM China Three Phase Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

OEM China Three Phase Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

OEM China Three Phase Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

OEM China Three Phase Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures

OEM China Three Phase Current Transformer - Hall Effect Current Sensor Split Core Transducer  – Malio detail pictures


Related Product Guide:

We insist on the principle of development of 'High quality, Efficiency, Sincerity and Down-to-earth working approach' to provide you with excellent service of processing for OEM China Three Phase Current Transformer - Hall Effect Current Sensor Split Core Transducer – Malio , The product will supply to all over the world, such as: Brasilia, Chicago, US, With strong technical strength and advanced production equipment, and SMS people purposefully , qualified, dedicated spirit of enterprise. Enterprises took the lead through the ISO 9001:2008 international quality management system certification, CE certification EU ; CCC.SGS.CQC other related product certification. We look forward to reactivating our company connection.
  • Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By Dinah from Jamaica - 2017.10.25 15:53
    The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Jocelyn from Malta - 2017.09.29 11:19
    Write your message here and send it to us